Technip’s practice is to specify gate valves with flushing connections at the base of the seat. To ensure positive isolation, the flushing connection can be used to remove any sediments that may be impact the contact of the gate with the seat. Another option is to orient the valve stem off of vertical in order to move the final seating location away from the low point, therefore reducing the chances of sediment to accumulate there.