For two stage desalting, injecting all the fresh wash water upstream of the second stage desalter provides the opportunity to use the lowest salt water on partially desalted crude which should result in the lowest level of salt in the desalted crude oil. Water from the second stage desalter is then used to provide wash water for the first stage. This water is typically split between being injected upstream of the exchanger train and upstream of the mix valve for the first stage desalter.