Typical operating conditions in a reformer do not result in platinum volitization. However, it is possible for Platinum to become volatile and come off the catalyst at very high temperatures. One place this can occur is in the Chlorination zone of the CCR Regeneration Tower, where slipping coked catalyst into an oxygen rich atmosphere can result in very high temperatures.